Blind and heating actuator 1 + 1gang flush-mounted with integral bus coupling unit, KNX, light grey | |
Art No. | 75341006 |
EAN No. | 4011334328551 |
P.U. | 1 part |
Price * | on demand |
Price Group |
Bus system | KNX |
Number of blinds/shutters outputs | 1 |
Fixing mode | flush-mounting |
Bus module detachable | no |
Operating mode | Operating mode can be set for blind, roller shutter/awning or ventilation flap |
|
|
|
Indicator lamp | no |
|
|
|
Bus system radio frequent | no |
Bus system LON | no |
Bus system Powernet | no |
|
|
|
Type of supply voltage | AC |
Max. switching capacity at | 230 V AC , 50/60 Hz |
Operating voltage over bus | 21…32 V DC |
External signal voltage necessary | yes |
Number of entry circuits | 3 |
Nominal current per heating output | 25 mA |
Switching current for electronic outputs | max. 25 mA |
Switching capacity for max. 1 motor | 600 VA |
Dimensions (Ø x H) | 53 x 28 mm |
Height | 81 mm |
|
|
|
Load cable length | ≈ 20 cm at 2x1.5mm² |
Cable length, bus + inputs (extendable to max. 5 m) | ≈ 33 cm |
Supported configuration modes | system |
|
|
|
Bus connection included | yes |
|
Modular expandability | no |
Actuators per channel | max. 2 |
|
|
|
|
|
Differentiation characteristic 3 - Sales | with integral bus coupling unit |
Protection index IP | IP30 |
Halogen free | no |
Operating temperature | -5…45 °C |
Storage/transport temperature | -20…70 °C |
Main design line | KNX |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
Manual for 75341004-75341005-75341006 - Window interface, blind actuator, heating actuator flush-mounted (EN, 2005-09) |
PDF, 365 KB | |
More (10) |
Order Overview for Actuators flush-mounted/surface-mounted Actuators flush-mounted/surface-mounted |
PDF, 464 KB |
Catalogue Chapter for Berker KNX - system Berker KNX - system |
PDF, 7,7 MB |
KNX Database (from ETS3) for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (2009-09) |
VD4, 274 KB | |
KNX Database (from ETS3) for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (2009-07) |
VD4, 218 KB | |
KNX Database (from ETS2) for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (2009-07) |
VD2, 257 KB | |
KNX Database (from ETS2) for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (2009-09) |
VD2, 264 KB |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
Application description ETS for 75341006 - Blind and heating actuator 1 + 1gang flush-mounted (EN, 2009-06) |
PDF, 1,3 MB | |
More (10) |
Product Data Sheet for 75341006 Blind and heating actuator 1 + 1gang flush-mounted with integral bus coupling unit, KNX, light grey |
PDF, 353 KB |